Ntu or kav l calculation 9.
Cooling tower pump head calculation pdf.
A improper application of tower bypass controls.
Choosing a cooling tower type 7.
For the tower piping circuit the pump must overcome the piping flow friction loss.
The pump head calculation depends on the type of system that the pump serves.
The recirculation rate and the temperature drop across the cooling tower are the two pieces of data needed to calculate the amount of water lost from the open recirculating cooling system due to evaporation.
The most common open system is the cooling tower portion of a chilled water system as depicted below.
Air in pump suction.
In this calculation cooling tower approach cooling tower range are important factors.
Consideration of by pass wall water 10.
Following items will be discussed and calculated in this article.
Printer friendly pdf here at r.
Correctly piping the suction and discharge of your cooling tower condenser water pump is critical.
Starting with the suction piping it is important to take precaution to avoid air pockets which can destroy a pump in pretty short order.
The cooling tower fans modulate in order to maintain the necessary condenser water supply temperature.
Deppmann we receive a continuous barrage of questions regarding concern over npsh net positive suction head and tower pump selections.
An equalizer is provided between multiple cooling towers to stop different water levels from occurring between cooling towers.
It is the most confusing set of values shown on a pump curve.
Velocity head and suction for pumps.
4 0 condenser water pump calculator inputs.
2 ump cavitation and loss of pumping ability as p hcaused by inadequate pump suction pressure.
Components of cooling towers 4.
526 charlotte avenue burkburnett tx 76354.
The difference between the cooling tower outlet water.
The condenser wate r pumps run at a constant speed flow.
Condenser system for vacuum creations and its types with design criteria.
Some fairly catastrophic events can occur if either is improperly installed.
Piping condenser cooling tower losses and valves.
Evaporation temperature drop.
Incorrect pump head estimation.
This week let s look at npsh r or net positive suction pressure required by the pump.
Unstable pump operational points as caused by.
Air flow arrangements 12.
Factors affecting cooling towers capacity 6.
Cooling towers performances 5.
Cooling tower types 3.
Cooling tower basic calculations.
As caused by tower pan vortex pan drain down or faulty bypass.
Pressure drops in cooling towers 11.